Seq #123 Thursday, July 3, 2008

3:30 PM-4:45 PM Metro Toronto Convention Centre Exhibit Hall D-E, Poster
Simulation and Drugs Study
 
1232  Clinical evaluation of implants following radical oral-cancer-surgery with/without adjuvant radiotherapy
S. LINSEN1, U. SCHMIDT-BEER1, M. MARTINI1, B. KOECK1, and H. STARK2, 1University of Bonn, Germany, 2Zentrum fur Zahn-Mund-und Kieferheikunde der Universitat, Bonn, Germany
1233  Advanced Glycation Endproducts (AGEs) and Rat Dental Implant Osseointegration
D. QUINTERO, J.N. WINGER, N.N. DO, Y. VIERA, W. RUAN, C.A. LAPP, M. YU, B. TOBIAS, and J. BORKE, Medical College of Georgia, Augusta, USA
1234  WITHDRAWN
1235  Phisical Terapies and Primary Bone Reparation in Implantoprosthesis
M. CORIGLIANO, International Academy of Implantoprosthesis and Osteoconnection, Rome, Italy, E. BALDONI, Università di Sassari, Italy, and A. CIPOLLINA, Rome, Italy
1236  Biofilm Formation on Amorphous Carbon and Titanium Films
S.E. RODIL1, A. ALMAGUER-FLORES1, R. OLIVARES-NAVARRETE2, L.A. XIMENEZ-FYVIE3, and A. LECHUGA-HERNANDEZ3, 1Universidad Nacional Autonoma de Mexico, Instituto de Investigaciones en Materiales, Mexico, 2Georgia Institute of Technology, Atlanta, USA, 3Universidad Nacional Autonoma de Mexico. Facultad de Odontologia, Mexico city, Mexico
1237  Bone Density Around Endosseous Implants In Patients Taking Alendronate (Fosamax®)
G. GRIFFITHS, Veterans Administration Medical Center, Dallas, TX, USA
1238  Effect of calcium,vitamin D on implant in ovariectomized rats
S.H. SHIN1, J.Y. LEE1, I.K. CHUNG1, W.W. SONG1, E.G. JUNG1, G.C. KIM1, and C.H. KIM2, 1Pusan National University, Busan, South Korea, 2Dong-A University, Busan, South Korea
1239  WITHDRAWN
1240  Implant-Bone Interface Biomechanics Distribution in Immediate-Loading Implants of Different Sizes
X. DING, X. ZHU, and X. ZHANG, The First Affiliated Hospital of Wenzhou Medical College, China
1241  Influence of implant shape and placement design to stress distribution
M. SUTPIDELER, Military Hospital, Izmir, Turkey, and S. ECKERT, Mayo Clinic, Rochester, MN, USA
1242  WITHDRAWN
1243  Orthodontic mini-implant design using the FE and Taguchi method
Y.-H. LIN1, C.-L. LIN1, C.-H. LIN1, and J.-H. YU2, 1Chang Gung University, Tao-Yuan, Taiwan, 2China Medical University, Taichung, Taiwan
1244  Finite Element Analysis of Implant-embedded Maxilla Model from CT Data
N. OKUMURA, R. STEGAROIU, H. NISHIYAMA, K. KUROKAWA, E. KITAMURA, T. HAYASHI, and S. NOMURA, Niigata University, Japan
1245  Biomechanical Analysis of an Implant Splinted to Endodontically treated Tooth
S.-F. HUANG1, J.-C. WANG2, and C.-L. LIN1, 1Chang Gung University, Tao-Yuan, Taiwan, 2Kaohsiung Medical University, Kaohsiung City, Taiwan
1246  Isotropic Heterogeneous FEM Model versus Isotropic and Anisotropic Homogeneous Models
R. STEGAROIU1, S. EJIRI1, K. KUROKAWA1, T. SATO1, Y. SATO2, and S. NOMURA1, 1Niigata University, Japan, 2Showa University, Tokyo, Japan
1247  Effects of sizes and designs on an immediate-load maxillary implant
H.-L. HUANG1, J.-T. HSU1, L.-J. FUH1, M.-G. TU1, M.Y. CHEN2, and Y.-W. SHEN1, 1China Medical University, Taichung, Taiwan, 2China Medical University Hospital, Taichung, Taiwan
1248  Effects of cortical bone thickness on an immediate-load implant
W.-C. LIAO1, H.-L. HUANG1, J.-T. HSU1, L.-J. FUH1, M.-G. TU2, W.-H. CHENG1, and H.-N. KUO3, 1China Medical University, Taichung, Taiwan, 2China Medical University Hospital, Taichung, Taiwan, 3Metal Industries Research and Development Centre, Kaohsiung, Taiwan
1249  WITHDRAWN
1250  Minimum number of implants for restoring maxillary edentulous situations
Y. MAEDA, M. SANO, K. IKEBE, and T. GONDA, Osaka University, Japan
1251  Influence of cusp inclination in implant supported dentures
R.M. FALCÓN-ANTENUCCI1, E.P. PELLIZZER1, P.S.P.D. CARVALHO1, P.Y. NORITOMI2, J.V.L. SILVA2, A.Y. UEHARA2, and D.T. KEMMOKU2, 1Universidade Est. Paulista Julio Mesquita, Araçatuba, Brazil, 2CenPRA - Centro de Pesquisas Renato Archer, Campinas, Brazil
1252  Photoelastic analysis: prosthesis-retained cemented/screwed with different implant geometric configurations
E.P. PELLIZZER, É. ALMEIDA, R.M. FÁLCON-ANTENUCCI, J.V.Q. MAZARO, R. FERRAÇO, B.P. TONELLA, and P.S.P. CARVALHO, Universidade Est. Paulista Julio Mesquita, Araçatuba, Brazil
1253  Stress analysis of zirconia abutment
Y. NOGUCHI, S. AOYAGI, N. FUJII, and M. TAKAYAMA, GC Corporation, Tokyo, Japan
1254  Biomechanical Analysis of Craniofacial Implants: Effects of Loading Conditions
T. YAMAMORI, T. FURUHASHI, T. KATO, N. MATSUMURA, T. MORIKAWA, and K. SEINO, Ohu University, Koriyama, Japan
1255  WITHDRAWN
1256  Finite-Element Analysis via Microcomputed Tomography of Implant-supporting tissues
P.-C. CHANG, Y.J. SEOL, N. KIKUCHI, and W. GIANNOBILE, University of Michigan, Ann Arbor, USA
1257  Influence of ridge and implant location on mandibular RPD association
L.D.A.P. CUNHA, E.P. PELLIZZER, F.R. VERRI, J.A. PEREIRA, J.V.Q. MAZARO, H. GENNARI-FILHO, and M.C. GOIATO, Universidade Est. Paulista Julio Mesquita, Araçatuba, Brazil
1258  Stress Comparison Between Orthodontic Miniscrews Using Finite Element Analysis
J.K. POLLEI1, E.P. ROCHA2, and C.-C. KO1, 1University of North Carolina, Chapel Hill, USA, 2Araçatuba School of Dentistry, São Paulo State University - UNESP, Chapel Hill, NC, USA
1259  WITHDRAWN
1260  Effects of Length and Width of Microimplants on Stress Generation
G.R. WERNER1, B. ASBURY2, C.E. CIRAC1, and A.A. CAPUTO1, 1University of California - Los Angeles, USA, 2University of California, Los Angeles, USA
1261  Stress Distribution of Implant-Supported Fixed Partial Dentures with Cantilever Extension
A.M.M. MESQUITA, R.O.A. SOUZA, S.M.A. MICHIDA, A.N. KOJIMA, T.J.A. PAES-JUNIOR, M.A. BOTTINO, and E.T. KIMPARA, São Paulo State University (UNESP), São José dos Campos, Brazil

Back to the: Implantology Research Program

Back to the IADR 86th General Session & Exhibition

Top Level Search