| 1290 | Development of Virtual Waxing Up System with Haptic Interface M. KIKUCHI, N. SEKI, D. NASU, K. KOBAYASHI, and I. NAKAJIMA, Nihon University, Tokyo, Japan |
| 1291 | Sagital Condylar Inclincations of Four Articulators Using Electronic Pantography L.C. KELLY, and D.A. GIVAN, University of Alabama, Birmingham, USA |
| 1292 | Feasibility of Dental Assistants Obtaining Mandibular Movement Tracings Using Cadiax J.S. MARCUM, and M.J. EDGE, University of Louisville, KY, USA |
| 1293 | Osseotite Certain Attachment Mechanism Predictive for Adequacy of Implant-abutment Interface M. GROSS1, J.N. KENEALY2, and R.M. STACH2, 1Private Practice, Tel Aviv, Israel, 2Implant Innovations, Inc, Palm Beach Gardens, FL, USA |
| 1294 | Effect of Cement Type and Fit on Fracture of Zirconium R.E. DUFF, M.E. RAZZOOG, and M. SIERRAALTA, University of Michigan, Ann Arbor, USA |
| 1295 | Optimization of Marginal Gap of Empress II Restorations by Al2O3-powder S. LINSEN, C. FISCHER, and B. KOECK, University of Bonn, Germany |
| 1296 | Cut-off Values Estimation on VAS for Complete Denture Assessment Y. KAWAI1, H. AJIRO1, A. TAKEO1, Y. OHNO2, T. KONDOH1, A. GUNJI1, and K. KOBAYASHI1, 1Nihon University, Matsudo, Chiba, Japan, 2Nihon University, Matsudo Chiba, Japan |
| 1297 | Mixing quality of static and dynamic mixers for impression materials J. GRAMANN, and M. HARTUNG, 3M ESPE AG, Seefeld, Germany |
| 1298 | Investigation of Implant Angulation and Distortion of Master Impression C.M. SHARP, University of Tennessee College of Dentistry, Memphis, USA |
| 1299 | Influence of Trays and Tecniques on Accuracy of PVS Impressions A.W. HOYOS, and K. SODERHOLM, University of Florida, Gainesville, USA |
| 1300 | Microleakage of Crown Preparations Treated with Bonding Agents J.C. CHANG1, L.M. PINZON2, and T.M. VUU1, 1University of Texas - Houston Dental Branch, USA, 2University of California San Francisco, University of Texas - Houston / Health Science Ctr, USA |
| 1301 | The Significance of Gap and Overextension Measurement of Crowns A.F. BOECKLER, A. STADLER, and J.M. SETZ, Martin-Luther-University Halle-Wittenberg, Halle (Salle), Germany |
| 1302 | Microtomography Assessment of Cement Volume for a “Flexible” Post System M.H. AL-TAYYAN, D.C. WATTS, H.G. KURER, and A.J.E. QUALTROUGH, University of Manchester, United Kingdom |
| 1303 | Reinforcement of Structurally Compromised Roots for Aesthetic Dowel Systems M.F. AYAD, University of Tanta, Egypt, S.A. BAHANNAN, King Abdulaziz University, Faculty of Dentistry, Jeddah, Saudi Arabia, and S.F. ROSENSTIEL, The Ohio State University, Columbus, USA |
| 1304 | Fiber Reinforced Composite Pins R. SCORESBY, T. WILTSHIRE, W.M. JOHNSTON, and C. MACHADO, The Ohio State University College of Dentistry, Columbus, USA |
|