0434 Effect of disinfection on dimensional stability of C-silicone impression material
M.C. BALKAYA, G. AKGUNGOR, S. PAMUK, H. GUR, and O. KUTAY, University of Istanbul, Faculty of Dentistry, Turkey

<> 

 

 

Objectives:The purpose of this study is to determine the effect of disinfection on dimensional stability of C-silicone impression materials.

Methods: A stainless steel maxillary model was produced. Three tapering preparations were made, one incisal and two molar. 30 impressions were made of C-silicone (Alphasil, Omicron Dental, Germany) with metal tray and divided into 6 groups of 5 impressions each.

Group 1. No immersion, poured after 15 minutes (Supra stone, Kerr, Sybron, Romulus, Mich.).

Group 2. 15 minutes immersion in 1 % didecyldimethyl amonnium chlorid solution (Hexanios Laboratories Anios, France) and poured.

Group 3. No immersion, poured after 60 minutes.

Group 4. 15 minutes immersion in 1 % didecyldimethyl amonium chloride solution and poured after 45 minutes.

Group 5. No immersion and poured after 24 hours.

Group 6. 15 minutes immersion in 1 % didecyldimethyl amonium chloride solution and poured after 24 hours.

Accuracy of techniques was assessed by measuring interabutments (A,B), cross arch(C,D) and occlusogingival (E,F,G) distance on stone dies with 3-D contact measuring device (Tesa MS 6101 3D, Swiss). Data were analyzed with Kruskal-Wallis test.

Results: Mean deformation distances (µm) and standard deviations (SD) of different groups are shown in table..Disinfection procedure and time intervals for model pouring showed no significant differences among the groups.

Conclusion: It was found that the dimension stability of C-silicone impression material was not effected by applied disinfection procedure and time intervals for fabricating a model.

 

1.Group

2.Group

3.Group

4.Group

5.Group

6.Group

Distances

Mean (SD)

Mean (SD)

Mean (SD)

Mean (SD)

Mean (SD)

Mean (SD)

A

-40±0.114

-174±0.086

-241±0.126

-183±0.151

-167±0.083

-60±0.172

B

63±0.294

-116±0.084

-158±0.106

-113±0.137

-60±0.065

33±0.197

C

-30±0.158

171±0.115

245±0.149

-10±0.242

99±0.104

-127±0.194

D

15±0.148

-163±0.072

-208±0.103

-30±0.226

-166±0.082

57±0.163

E

-9±0.234

-50±0.147

-40±0.140

31±0.267

-152±0.061

45±0.186

F

-40±0.135

32±0.05

-10±0.065

28±0.031

113±0.047

78±0.083

G

64±0.055

76±0.031

82±0.047

111±0.056

82±0.137

105±0.072

Seq #69 - Fixed Prosthodontic Research, Preparations, and Impressions
10:15 AM-11:30 AM, Thursday, 11 March 2004 Hawaii Convention Center Exhibit Hall 1-2

Back to the Prosthodontics Research Program
Back to the IADR/AADR/CADR 82nd General Session (March 10-13, 2004)