| | |
| 2634 |
3:45 PM | Clinical trial of Empress 2 selfcuring Excite and Multilink luting materials A. BORRACCHINI, A. FABIANELLI, S. GRANDINI, and M. FERRARI, University of Siena, Italy |
| 2635 |
4:00 PM | In vivo performance of an experimental core ceramic for posterior FPDs J. ESQUIVEL-UPSHAW1, K.J. ANUSAVICE2, H. YOUNG2, J. JONES2, and M. YANG2, 1The University of Texas Health Science Center at San Antonio, USA, 2University of Florida, Gainesville, USA |
| 2636 |
4:15 PM | Evaluation of the three-dimensional internal fit of all-ceramic crowns (CEREC-3®) G. BORNEMANN1, S. LEMELSON1, H. CLAAS1, and R.G. LUTHARDT2, 1Georg-August-University Göttingen, Germany, 2Dresden University of Technology, Germany |
| 2637 |
4:30 PM | Effect of APF Treatment of the CEREC Ceramics on Bond Strength T. MASEKI, NIPPON DENTAL UNIVERSITY, TOKYO, Japan, A. SHIROTA, T. KIMISHIMA, Y. NARA, and H. TANAKA |
| 2638 |
4:45 PM | Margin Quality of CAD/CAM Inlays Using Resin and Compomer Luting Systems M. PFRETZSCHNER, R. FRANKENBERGER, S. BUDER, W.O. STROBEL, and N. KRAEMER, University of Erlangen, Germany |
| 2639 |
5:00 PM | The effect of cad/cam surface damage on flexural strength H.M. LIVINGSTON, B.A. FRANKLIN, D.K. ALEXANDER, and D.E. PARSELL, University of Mississippi School of Dentistry, Jackson, USA |
| 2640 |
5:15 PM | In vitro evaluation of CAD/CIM ceramic crowns L.A. ELLINGSEN, and D.J. FASBINDER, University of Michigan, Ann Arbor, USA |
| 2641 |
5:30 PM | Milling quality of Cerec 2 and Cerec 3 CAD/CAM crowns. A SEM investigation H. CLAAS, Private dental office, Witzenhausen, Germany, F. SCHÄFERS, private dental office, Hattorf, Germany, and C. KRANTZ, University of Goettingen, Germany |
| 2642 |
5:45 PM | Bond Strength of an Experimental Porcelain for Metal-Ceramics T. SATO1, K. TSUCHIHIRA1, H. MIURA1, K. IKUSHIMA2, and T. ISHIDA2, 1Tokyo Medical & Dental University, Japan, 2GC Corporation, Tokyo, Japan |
| 2643 |
6:00 PM | Effects of thermal stresses on the margin stability of a conventional metal ceramic system compared to a hydrothermal ceramic A. ZADRO, G. GIRARDELLO, A. MARSILIO, M. GRIGOLETTO, and P. PASSI, Dental School-University of Padua, Padova, Italy |
| 2644 |
6:15 PM | Shear bond strength between cast or milled titanium to ceramics D.K. OYAFUSO, M.P. NEISSER, M.A. BOTTINO, M.K. ITINOCHE, M.C.A. CARVALHO, and D.R. SILVA NETO, São José dos Campos University, UNESP - School of Dentistry, São Paulo, Brazil |
| 2645 |
6:30 PM | Bonding Surface Activation by Glow Discharge Treatment Improves Integrity of Porcelain-Fused-To-Metal(Captek®) Interfaces H. KIM, E. MONACO, Jr., M. PIAZZA, P. PSICHOGIOS, A. MEYER, and R. BAIER, University at Buffalo, NY, USA |
| 2646 |
6:45 PM | Comparison of a novel titanium-ceramic system with a commercial system using a torsional load testing method P. VARPAVAARA1, J. KIVILAHTI2, and M. KÖNÖNEN1, 1University of Helsinki, Finland, 2Helsinki University of technology, Espoo, Finland |
| 2647 |
7:00 PM | Effects of Bur Grit Size and Abutment Composition on Machinability of Ceramic Implant Abutments and Wear of Diamond Burs D.S. BLUE, J.A. GRIGGS, R.D. WOODY, and B.H. MILLER, Baylor College of Dentistry, a member of the Texas A&M University System Health Science Center, Dallas, USA |
|