Seq #246 Friday, 8 March 2002

3:45 PM-5:00 PM San Diego Convention Center Exhibit Hall C, Poster Session
Other Ceramics and Cements
 
2634  3:45 PM Clinical trial of Empress 2 selfcuring Excite and Multilink luting materials
A. BORRACCHINI, A. FABIANELLI, S. GRANDINI, and M. FERRARI, University of Siena, Italy
2635  4:00 PM In vivo performance of an experimental core ceramic for posterior FPDs
J. ESQUIVEL-UPSHAW1, K.J. ANUSAVICE2, H. YOUNG2, J. JONES2, and M. YANG2, 1The University of Texas Health Science Center at San Antonio, USA, 2University of Florida, Gainesville, USA
2636  4:15 PM Evaluation of the three-dimensional internal fit of all-ceramic crowns (CEREC-3®)
G. BORNEMANN1, S. LEMELSON1, H. CLAAS1, and R.G. LUTHARDT2, 1Georg-August-University Göttingen, Germany, 2Dresden University of Technology, Germany
2637  4:30 PM Effect of APF Treatment of the CEREC Ceramics on Bond Strength
T. MASEKI, NIPPON DENTAL UNIVERSITY, TOKYO, Japan, A. SHIROTA, T. KIMISHIMA, Y. NARA, and H. TANAKA
2638  4:45 PM Margin Quality of CAD/CAM Inlays Using Resin and Compomer Luting Systems
M. PFRETZSCHNER, R. FRANKENBERGER, S. BUDER, W.O. STROBEL, and N. KRAEMER, University of Erlangen, Germany
2639  5:00 PM The effect of cad/cam surface damage on flexural strength
H.M. LIVINGSTON, B.A. FRANKLIN, D.K. ALEXANDER, and D.E. PARSELL, University of Mississippi School of Dentistry, Jackson, USA
2640  5:15 PM In vitro evaluation of CAD/CIM ceramic crowns
L.A. ELLINGSEN, and D.J. FASBINDER, University of Michigan, Ann Arbor, USA
2641  5:30 PM Milling quality of Cerec 2 and Cerec 3 CAD/CAM crowns. A SEM investigation
H. CLAAS, Private dental office, Witzenhausen, Germany, F. SCHÄFERS, private dental office, Hattorf, Germany, and C. KRANTZ, University of Goettingen, Germany
2642  5:45 PM Bond Strength of an Experimental Porcelain for Metal-Ceramics
T. SATO1, K. TSUCHIHIRA1, H. MIURA1, K. IKUSHIMA2, and T. ISHIDA2, 1Tokyo Medical & Dental University, Japan, 2GC Corporation, Tokyo, Japan
2643  6:00 PM Effects of thermal stresses on the margin stability of a conventional metal ceramic system compared to a hydrothermal ceramic
A. ZADRO, G. GIRARDELLO, A. MARSILIO, M. GRIGOLETTO, and P. PASSI, Dental School-University of Padua, Padova, Italy
2644  6:15 PM Shear bond strength between cast or milled titanium to ceramics
D.K. OYAFUSO, M.P. NEISSER, M.A. BOTTINO, M.K. ITINOCHE, M.C.A. CARVALHO, and D.R. SILVA NETO, São José dos Campos University, UNESP - School of Dentistry, São Paulo, Brazil
2645  6:30 PM Bonding Surface Activation by Glow Discharge Treatment Improves Integrity of Porcelain-Fused-To-Metal(Captek®) Interfaces
H. KIM, E. MONACO, Jr., M. PIAZZA, P. PSICHOGIOS, A. MEYER, and R. BAIER, University at Buffalo, NY, USA
2646  6:45 PM Comparison of a novel titanium-ceramic system with a commercial system using a torsional load testing method
P. VARPAVAARA1, J. KIVILAHTI2, and M. KÖNÖNEN1, 1University of Helsinki, Finland, 2Helsinki University of technology, Espoo, Finland
2647  7:00 PM Effects of Bur Grit Size and Abutment Composition on Machinability of Ceramic Implant Abutments and Wear of Diamond Burs
D.S. BLUE, J.A. GRIGGS, R.D. WOODY, and B.H. MILLER, Baylor College of Dentistry, a member of the Texas A&M University System Health Science Center, Dallas, USA

Back to the: Dental Materials: III - Ceramics and Cements Program

Back to the IADR/AADR/CADR 80th General Session (March 6-9, 2002)

Top Level Search